摘要: 建立了高效液相色谱-电感耦合等离子体质谱(HPLC-ICP-MS)联用检测硒酸盐(SeVI)、亚硒酸盐(SeIV)、硒代蛋氨酸(SeMet)、硒代胱氨酸(SeCys2)和硒代乙硫氨酸(SeEt)的方法。采用Hamilton PRP X-100色谱柱(250 mm×4.6 mm, 5 μm),使用5 mmol/L的柠檬酸溶液(pH 4.5)作为流动相,电感耦合等离子体质谱(ICP-MS)检测,在21 min内可以完全分离5种硒形态。各形态硒的线性相关系数均大于0.9995, SeVI、SeIV、SeMet、SeCys2、SeEt的检出限分别为0.4、0.4、5.6、0.9、1.2 μg/L。探讨了不同提取方法的提取效果,鲜蘑菇和猪肉样品加标回收实验表明,对水溶性良好的无机硒和硒代蛋氨酸而言,采用柠檬酸溶液提取的效果非常好,SeIV和SeVI的回收率均在100%左右,SeMet的回收率为85.0%~95.3%;用蛋白酶水解提取,SeCys2和SeEt的回收率为79.9%~91.5%。该方法可完全满足食品中这5种硒形态的准确定量分析。

关键词: 电感耦合等离子体质谱, 高效液相色谱, 硒化合物

Abstract: An analytical method for selenium species of selenate (SeVI), selenite (SeIV), selenomethionine (SeMet), selenocystine (SeCys2) and selenoethionine (SeEt) was established using high performance liquid chromatography with inductively coupled plasma mass spectrometry (HPLC-ICP-MS). A Hamilton PRP X-100 reversed-phase anion exchange column (250 mm×4.6 mm, 5 μm)with a 5 mmol/L citric acid buffer solution (pH 4.5, adjusted with 20% (v/v) ammonia ) as mobile phase was used for separation,and ICP-MS was used for detection. The five species were completely separated within 21 min. All the linear correlation coefficients of the five selenium species were greater than 0.9995, and the detection limits of SeVI, SeIV, SeMet, SeCys2, SeEt were 0.4, 0.4, 5.6, 0.9 and 1.2 μg/L, respectively. The extraction procedure was studied for fresh mushroom and pork samples. For water-soluble selenium compounds, citric acid was a good extraction solution, and the recoveries were around 100% for inorganic selenium and in the range of 85.0%~95.3% for SeMet; but worse for SeCys2 and SeEt. As for the proteinase K, the recoveries of SeCys2 and SeEt were raised to the range of 79.9%~91.5%. The method has the advantages of simple operation and good accuracy, and can be used for the quantitative determination of the five selenium species in food.