Determination of arsanilic acid and sulfanilic acid as adulterant in feed additives by reversed-phase high performance liquid chromatography

XU Jinping1*, HE Heng2, XU Mengyi1, QU Yanhua1   

  1. 1. School of Pharmacy, Tongji Medical College of Huazhong University of Science and Technology, Wuhan 430030, China; 2. College of Post and Telecommunication of Wuhan Institute of Technology, Wuhan 430073, China
  • Received:2009-07-30 Revised:2009-09-30 Online:2010-02-28 Published:1981-06-25
  • Contact: XU Jinping

Abstract: A reversed-phase high performance liquid chromatographic (RP-HPLC) method was established for the determination of arsanilic acid and sulfanilic acid as adulterant in the feed additives. The separation was carried out on a Waters Bondapak C18 column, and methanol-water (pH 2.9 adjusted by 0.01 mol/L phosphoric acid) (1:4, v/v) was used as the mobile phase with a flow rate of 1.0 mL/min. A diode array detector was used at 244 nm as the detection wavelength. Arsanilic acid and sulfanilic acid were separated within 3 min. The linear ranges all were 5~200 mg/L and the detection limits (S/N=3) were 0.20 and 0.15 mg/L for arsanilic acid and sulfanilic acid, respectively. This method is simple and rapid, and suitable for the simultaneous determination of arsanilic acid and sulfanilic acid in feed additives.

Key words: adulterant, arsanilic acid, feed additive , sulfanilic acid, reversed-phase high performance liquid chromatography (RP-HPLC)